{"product_id":"carbon-dioxide-and-oxygen-analyzer-for-headspace","title":"Headspace-Analysator | Kohlendioxid \u0026 Sauerstoff ","description":"\u003cp\u003e\u003ciframe title=\"YouTube-Videoplayer\" src=\"https:\/\/www.youtube.com\/embed\/YrJIspqqg8A?si=IxkQNfAmsr9sadY6\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"s1\"\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"s1\"\u003eMarke: \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003eFORENSICS DETECTORS\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"s1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003eModell:\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003eFD-600-HA-CO2-O2\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"s2\"\u003e\u003cbr\u003e\u003cstrong\u003eBenutzerhandbuch:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e\u003cspan\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/600_Manual_v7.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHier klicken\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/600_Manual_v2.0.pdf?v=1588459336\" target=\"_blank\"\u003e\u003cspan class=\"s2\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cb\u003eDatenprotokollierung: \u003c\/b\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.forensicsdetectors.com\/pages\/fd-600\" target=\"_blank\"\u003eHier klicken\u003c\/a\u003e \u003cbr\u003e\u003cstrong\u003eBlogartikel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/blogs\/articles\/guide-headspace-analyzers\" target=\"_blank\"\u003eHier klicken\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eEigenschaften:\u003c\/b\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e🎆 \u003cstrong\u003eHEADSPACE:\u003c\/strong\u003e CO2 (NDIR-Sensor) und O2 (elektrochemischer Sensor) Headspace-Analyse. Werkskalibriert.\u003c\/li\u003e\n\u003cli\u003e🌈 \u003cstrong\u003eFARBE:\u003c\/strong\u003e Farbdisplay und Grafikfunktionen ermöglichen eine intuitive Bedienung.\u003c\/li\u003e\n\u003cli\u003e📲\u003cstrong\u003e DATENPROTOKOLLIERUNG:\u003c\/strong\u003e USB-Aufladung und Echtzeit-Datenerfassung am Computer. Wird mit Spritzen, Filtern, Luer-Lock-Anschlüssen und 100 Septen geliefert.\u003c\/li\u003e\n\u003cli\u003e💪 \u003cstrong\u003eROBUST:\u003c\/strong\u003e Robustes Design aus hochfestem ABS mit rutschfestem Gummigriff. Wasserfest, staubdicht und explosionsgeschützt.\u003c\/li\u003e\n\u003cli\u003e🕵️ \u003cstrong\u003eZUVERLÄSSIG:\u003c\/strong\u003e 1 Jahr eingeschränkte Garantie. Wird mit einem unterschriebenen und datierten Kalibrierzertifikat geliefert.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eDetails:\u003c\/b\u003e Unser CO2- und O2-Analysator ist die perfekte Lösung für Ihre Verpackungsanalyseprobleme. Der Headspace-Analysator untersucht Ihre Produkte mit modifizierter Atmosphäre (MAP), um den Sauerstoff- und\/oder Kohlendioxidgehalt zu messen. Der FORENSICS CO2- und O2-Analysator ist eine ausgezeichnete Wahl mit intuitiver Bedienung. Basierend auf unserer Industrie-Analysatorplattform verfügt dieses Gerät über eine eingebaute Pumpe, die einfach zu bedienen und sehr portabel ist. Stecken Sie einfach die Nadelspitze der Sonde durch eine Septumdichtung in die Lebensmittelverpackung. Das Septum sorgt für eine dichte Abdichtung und verhindert, dass Luft durch das Einstichloch in die Verpackung gelangt. Mit voller Benutzerkontrolle saugt die eingebaute Pumpe die für die Analyse benötigte kleine oder große Luftmenge an. Die Pumpe kann jederzeit ausgeschaltet werden, um die richtige Luftmenge zu entnehmen, da der Verpackungskopfraum je nach Produkt variiert. Ausgestattet mit Farbdisplay, großen Ziffern und Echtzeit-Grafik auf dem Bildschirm. Der Detektor ist mit einem fortschrittlichen elektrochemischen Sauerstoffsensor ausgestattet. Der interne 32-Bit-Mikroprozessor ermöglicht Benutzerkalibrierung, Ein-\/Ausschalten des Flusses und Teststeuerung. Typische Messungen dauern weniger als 30 Sekunden.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLieferumfang:\u003c\/strong\u003e O2\/CO2-Analysator mit Magnetrückseite, Benutzerhandbuch, zertifiziertes Kalibrierzertifikat, USB-Ladekabel, Ladegerät, 2 Nadeln, 2 Filter, 100 Klebesepten und Schläuche mit Luer-Lock-Anschlüssen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKalibrieroptionen\u003cspan\u003e:  \u003c\/span\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/hydrogen-sulfide-bump-gas\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/multigas-calibration\" rel=\"noopener\" target=\"_blank\"\u003eKalibrierservice von Forensics Detectors\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/pages\/fd-601\"\u003eKalibrierungsanleitung (DIY)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eKalibrierkit \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e(DIY separat erhältlich):\u003c\/strong\u003e  \u003c\/span\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/ammonia-gas-10ppm\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/t-piece-and-tubing\" target=\"_blank\"\u003eKalibrier-T-Stück \u0026amp; Schlauch\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/ammonia-gas-10ppm\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/carbon-dioxide-gas-10ppm\" target=\"_blank\"\u003eKalibrier-Gas (CO2 in N2 ausbalanciert)\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/gas-regulator-mini-flowmeter\" target=\"_blank\"\u003eKalibrier-Gasregler (C10)\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/n2-n2-bump-gas\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/co2-bumpgas\" target=\"_blank\"\u003eBump-Gas (CO2 in N2 ausbalanciert)\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/n2-n2-bump-gas\" target=\"_blank\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/gas-mix-bump-gas\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cstrong\u003eZubehör und Ersatzteile \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e(separat erhältlich):\u003c\/strong\u003e  \u003c\/span\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/collections\/probes\" target=\"_blank\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/oxygen-sensor-alpha\" target=\"_blank\"\u003eGassensor-Ersatz (O2)\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/carry-case-waterproof\" target=\"_blank\"\u003eWasserdichtes Gehäuse für Gasmessgerät\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/detector-stand-universal\" target=\"_blank\"\u003eStänder für Gasmessgerät\u003cbr\u003e\u003c\/a\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/headspace-kit?_pos=1\u0026amp;_sid=125e8880c\u0026amp;_ss=r\" target=\"_blank\"\u003eHeadspace-Kit, Nadeln, Filter, Schläuche, Septen\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSauerstoff (O2) Erkennung:\u003c\/strong\u003e 0 - 30% mit 0,01% Auflösung\u003cbr\u003e\u003cstrong\u003eKohlendioxid (CO2) Erkennung:\u003c\/strong\u003e 0 - 100% mit 0,01% Auflösung\u003cbr\u003e\u003cstrong\u003eFehler:\u003c\/strong\u003e ≤ ± 3% F.S.\u003cbr\u003e\u003cstrong\u003eAnsprechzeit:\u003c\/strong\u003e \u0026lt;60 Sekunden\u003cbr\u003e\u003cstrong\u003eLager- \/ Betriebstemperatur:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e0°F - 122°F\u003cstrong\u003e\u003cbr\u003eLager- \/ Betriebsfeuchtigkeit:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u0026lt;95% r.F.\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eBatterie:\u003c\/strong\u003e DC 3,7 V Li-Ion Akku, 3200 mAh\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eGassensortyp: \u003c\/span\u003e\u003c\/strong\u003eElektrochemischer Gassensor (O2) und NDIR-Gassensor (CO2)\u003cbr\u003e\u003cstrong\u003eLebensdauer Gassensor:\u003c\/strong\u003e 2 - 3 Jahre (O2), \u0026gt; 5 Jahre (CO2)\u003cbr\u003e\u003cstrong\u003eEmpfohlener Kalibrierungszeitraum: \u003c\/strong\u003e12 Monate\u003cbr\u003e\u003cstrong\u003eExplosionsschutzklasse:\u003c\/strong\u003e ATEX zertifiziert Ex ib IIC T4 Gb\u003cbr\u003e\u003cstrong\u003eGewicht:\u003c\/strong\u003e 14 oz\u003cbr\u003e\u003cstrong\u003eAbmessungen:\u003c\/strong\u003e 5,1 in × 2,6 in x 1,2 in\u003cbr\u003e\u003cstrong\u003eLadezeit:\u003c\/strong\u003e 4 Stunden\u003cbr\u003e\u003cstrong\u003eBetriebsdauer:\u003c\/strong\u003e \u0026gt; 10 Stunden\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eMinimales erforderliches Headspace-Volumen: \u003c\/strong\u003e200 ml\u003cbr\u003e\u003cstrong\u003ePumpenrate:\u003c\/strong\u003e 0,1 LPM - 0,3 LPM (100 - 300 cc\/min)\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eAlarm:\u003c\/strong\u003e LED-Alarm\u003cbr\u003e\u003cstrong\u003eKalibrierungsort (USA):\u003c\/strong\u003e Los Angeles, Kalifornien, USA\u003cbr\u003e\u003cstrong\u003eKalibrierungsstandard (USA):\u003c\/strong\u003e USA NIST rückverfolgbare Gasquelle\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eKalibrierungsort (Europa):\u003c\/strong\u003e Athen, Griechenland\u003cbr\u003e\u003cstrong\u003eKalibrierungsstandard (Europa):\u003c\/strong\u003e Europäische NPL rückverfolgbare Gasquelle\u003cbr\u003e\u003c\/p\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":31458777923628,"sku":"FD-600-HA-CO2-O2","price":1295.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/Image1-FD-600-HA-CO2-O2-Shopify.jpg?v=1762366005","url":"https:\/\/www.forensicsdetectors.com\/de-de\/products\/carbon-dioxide-and-oxygen-analyzer-for-headspace","provider":"Forensics Detectors","version":"1.0","type":"link"}