{"product_id":"carbon-dioxide-analyzer-for-headspace","title":"Headspace-Analysator | Kohlendioxid | 0 - 100 % | ","description":"\u003cp\u003e\u003ciframe title=\"YouTube-Videoplayer\" src=\"https:\/\/www.youtube.com\/embed\/-xFHC61P38o?si=HpeyDAGZgQB2Xmvo\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan class=\"s1\"\u003eMarke: \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003eFORENSICS DETECTORS\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"s1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003eModell:\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003eFD-600-HA-CO2\u003cbr\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"s1\"\u003e\u003cstrong\u003eDatenprotokollierung:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.forensicsdetectors.com\/pages\/fd-600\" target=\"_blank\"\u003eHier klicken\u003cbr\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"s2\"\u003e\u003cstrong\u003eBenutzerhandbuch:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e\u003cspan\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/600_Manual_v7.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHier klicken\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eBlogartikel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/blogs\/articles\/guide-headspace-analyzers\" target=\"_blank\"\u003eHier klicken\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eEigenschaften:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e🎆  \u003cstrong\u003eMAP-ANALYSE:\u003c\/strong\u003e CO2 (NDIR-Sensor) Headspace-Analyse. \u003c\/li\u003e\n\u003cli\u003e🌈  \u003cstrong\u003eFARBDISPLAY:\u003c\/strong\u003e Farbdisplay und Grafikfunktionen. Computer-Datenprotokollierung.\u003c\/li\u003e\n\u003cli\u003e📲 \u003cstrong\u003e BATTERIE:\u003c\/strong\u003e USB-Aufladung für den leichten Handbetrieb des Instruments. Wird mit Spritzen, Filtern, Luer-Lock-Anschlüssen und 100 Septen geliefert.\u003c\/li\u003e\n\u003cli\u003e💪  \u003cstrong\u003eROBUST:\u003c\/strong\u003e Robustes Design aus hochfestem ABS und rutschfestem Gummigriff. Wasserfest, staubdicht und explosionsgeschützt.\u003c\/li\u003e\n\u003cli\u003e🕵️  \u003cstrong\u003eZUVERLÄSSIG:\u003c\/strong\u003e 1 Jahr eingeschränkte Garantie. Wird mit einem unterschriebenen und datierten Kalibrierzertifikat geliefert. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDetails:\u003c\/strong\u003e Unser Kohlendioxid-(CO2)-Headspace-Analysator ist die perfekte Lösung für Ihre Verpackungsanalyseprobleme.\u003cspan\u003e Der Headspace-Analysator untersucht Ihre Produkte mit modifizierter Atmosphäre (MAP), um den Kohlendioxid-Modifikationsgrad zu messen. Der FORENSICS CO2-Analysator ist eine ausgezeichnete Wahl mit intuitiver Bedienung. Basierend auf unserer Industrie-Analysatorplattform verfügt dieses Gerät über eine eingebaute Pumpe, die einfach zu bedienen und sehr portabel ist. Stecken Sie einfach die Nadelspitze der Sonde durch eine Septumdichtung in die Lebensmittelverpackung. Das Septum sorgt für eine dichte Abdichtung und verhindert, dass Luft durch das Einstichloch in die Verpackung gelangt. Mit voller Benutzerkontrolle saugt die eingebaute Pumpe die für die Analyse benötigte kleine oder große Luftmenge an. Die Pumpe kann jederzeit ausgeschaltet werden, um die richtige Luftmenge zu entnehmen, da der Verpackungs-Headspace je nach Produkt variiert. Ausgestattet mit Farbdisplay, großen Ziffern und Echtzeit-Grafik auf dem Bildschirm. Der Detektor ist mit einem fortschrittlichen NDIR-CO2-Sensor ausgestattet. Der interne 32-Bit-Mikroprozessor ermöglicht Benutzerkalibrierung, Ein-\/Ausschalten des Flusses und Teststeuerung. Typische Tests dauern weniger als 30 Sekunden.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLieferumfang:\u003c\/strong\u003e CO2-Analysator mit Magnetrückseite, Benutzerhandbuch, zertifiziertes Kalibrierzertifikat, USB-Ladekabel, Ladegerät, 2 x Nadeln, 2 x Filter, 100 x Klebesepten und Schläuche mit Luer-Lock-Anschlüssen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKalibrieroptionen\u003cspan\u003e:  \u003c\/span\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/hydrogen-sulfide-bump-gas\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/single-gas-calibration\" target=\"_blank\"\u003eKalibrierservice von Forensics Detectors\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/pages\/fd-601\"\u003eKalibrierungsanleitung (DIY)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eKalibrierkit \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e(DIY separat erhältlich):\u003c\/strong\u003e  \u003c\/span\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/ammonia-gas-10ppm\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003cmeta charset=\"utf-8\"\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/t-piece-and-tubing\" target=\"_blank\"\u003eKalibrier-T-Stück \u0026amp; Schlauch\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/ammonia-gas-10ppm\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/carbon-dioxide-gas-10ppm\" target=\"_blank\"\u003eKalibrier-Gas (CO2 in N2 ausbalanciert)\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/gas-regulator-mini-flowmeter\" target=\"_blank\"\u003eKalibrier-Gasregler (C10)\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/n2-n2-bump-gas\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/co2-bumpgas\" target=\"_blank\"\u003eBump-Gas (CO2 in N2 ausbalanciert)\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/n2-n2-bump-gas\" target=\"_blank\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/gas-mix-bump-gas\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cstrong\u003eZubehör und Ersatzteile \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e(separat erhältlich):\u003c\/strong\u003e  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/carry-case-waterproof\" target=\"_blank\"\u003eWasserdichtes Schutzgehäuse für Gasdetektor\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/detector-stand-universal\" target=\"_blank\"\u003eUniversal-Ständer für Gasdetektor\u003cbr\u003e\u003c\/a\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/headspace-kit?_pos=1\u0026amp;_sid=125e8880c\u0026amp;_ss=r\" target=\"_blank\"\u003eHeadspace-Kit, Nadeln, Filter, Schläuche, Septen\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eKohlendioxid (CO2) Erkennung:\u003c\/strong\u003e 0 - 100% mit 0,01% Auflösung\u003cbr\u003e\u003cstrong\u003eFehler:\u003c\/strong\u003e ≤ ± 3% F.S.\u003cbr\u003e\u003cstrong\u003eAnsprechzeit:\u003c\/strong\u003e \u0026lt;60 Sekunden\u003cbr\u003e\u003cstrong\u003eLager- \/ Betriebstemperatur:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e0°F - 122°F\u003cstrong\u003e\u003cbr\u003eLager- \/ Betriebsfeuchtigkeit:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u0026lt;95% r.F.\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eBatterie:\u003c\/strong\u003e DC 3,7V Li-Ion-Akku, 3200 mAh\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003e\u003cspan\u003eGassensortyp: \u003c\/span\u003e\u003c\/strong\u003eNDIR-Gassensor \u003cstrong\u003e\u003cspan\u003e\u003cbr\u003eLebensdauer des Gassensors: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u0026gt; 5 Jahre\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eEmpfohlener Kalibrierungszeitraum: \u003c\/strong\u003e12 Monate\u003cbr\u003e\u003cstrong\u003eExplosionsschutzklasse:\u003c\/strong\u003e ATEX-zertifiziert Ex ib IIC T4 Gb\u003cbr\u003e\u003cstrong\u003eGewicht:\u003c\/strong\u003e 14 oz\u003cbr\u003e\u003cstrong\u003eAbmessungen:\u003c\/strong\u003e 5,1 in × 2,6 in x 1,2 in\u003cbr\u003e\u003cstrong\u003eLadezeit:\u003c\/strong\u003e 3 Stunden\u003cbr\u003e\u003cstrong\u003eBetriebsdauer:\u003c\/strong\u003e \u0026gt; 10 Stunden\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eMinimales erforderliches Headspace-Volumen: \u003c\/strong\u003e200 ml\u003cbr\u003e\u003cstrong\u003ePumpenrate:\u003c\/strong\u003e 0,1 LPM - 0,3 LPM (100 - 300 cc\/min)\u003cbr\u003e\u003cstrong\u003eAlarm:\u003c\/strong\u003e LED-Alarm\u003cbr\u003e\u003cstrong\u003eKalibrierungsort (USA):\u003c\/strong\u003e Los Angeles, Kalifornien, USA\u003cbr\u003e\u003cstrong\u003eKalibrierungsstandard (USA):\u003c\/strong\u003e USA NIST rückverfolgbare Gasquelle\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eKalibrierungsort (Europa):\u003c\/strong\u003e Athen, Griechenland\u003cbr\u003e\u003cstrong\u003eKalibrierungsstandard (Europa):\u003c\/strong\u003e Europäische NPL rückverfolgbare Gasquelle\u003cbr\u003e\u003c\/p\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":34799071396003,"sku":"FD-600-HA-CO2","price":995.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/Image1-FD-600-HA-CO2-Shopify.jpg?v=1762365726","url":"https:\/\/www.forensicsdetectors.com\/de-fr\/products\/carbon-dioxide-analyzer-for-headspace","provider":"Forensics Detectors","version":"1.0","type":"link"}