{"product_id":"co2-monitor-usa-nist-calibration","title":"CO2-Messgerät | Wandmontage | 0–5000 ppm | EU-Kalibrierzertifikat Enthalten","description":"\u003cp\u003e\u003cstrong\u003e\u003cb\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/h__7WMdmH8s\" title=\"YouTube-Video-Player\"\u003e\u003c\/iframe\u003eMarke:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eFORENSICS DETECTORS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModell:\u003c\/strong\u003e\u003cspan\u003e FD-60-CO2-PPM\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eBenutzerhandbuch:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/FIXED_Manual_v5.0.pdf\" target=\"_blank\"\u003eHier klicken\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003eBlog-Artikel:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.forensicsdetectors.com\/blogs\/articles\/guide-to-carbon-dioxide-monitors\" target=\"_blank\"\u003eHier klicken\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e🚀\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINDUSTRIELL:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobuster fest installierter \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eCO2-Detektor, Messbereich 0 - 5000 ppm. Dualer NDIR-Sensor. Wird WERKSKALIBRIERT geliefert. \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e🌎\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eANWENDUNG:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFernbedienung bis zu 8 Meter. 2 x Relais-Alarm-Schalter (50W) zur Steuerung von Ventilatoren, Pumpen, elektrischen Geräten, Garagentoren oder zusätzlichen Alarmen.\u003c\/li\u003e\n\u003cli\u003e🎆\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eMERKMALE:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGroßer LED-Alarm und Summer. Einstellbare akustische und visuelle Signale. Fernbedienung.\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/pages\/fd-60-modbus-rs485\"\u003eRS485 MODBUS-Ausgang\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eund\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/youtu.be\/IEJBg6nlIJE\"\u003eAnalogausgang (4-20 mA)\u003c\/a\u003e für Fernüberwachung und Datenprotokollierung.\u003c\/li\u003e\n\u003cli\u003e💪\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eROBUST:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExplosions-, staub-, wasser- und flammgeschützt. Explosionsschutzklasse: Exd ⅡC T6 Gb mit IP65-Gehäuseschutz.\u003c\/li\u003e\n\u003cli\u003e🕵️\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eVERTRAUEN:\u003c\/strong\u003e\u003cspan\u003e 1 Jahr eingeschränkte Garantie. Wird mit einem unterschriebenen und datierten Kalibrierzertifikat geliefert. \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDetails:\u003c\/strong\u003e Dies ist unser fest installierter CO2-Monitor, ein wandmontierter Gasdetektor für Arbeitsbereiche, Labore, Garagen, Prozessräume, Verbrennungskontrollräume, Raffinerien, Tankstellen, Heizräume, beengte Räume und viele weitere. Hervorragend für kontinuierliche Überwachung und Alarmierung. Ein robustes Gerät, das an der Wand montiert wird und mit LED- und Summeralarm sofortige Maßnahmen ermöglicht. Häufig gekauft für Kryogenik, beengte Räume, Stickstoffanwendungen, Industrie, Fabriken, CO2-Einfrieren und vieles mehr.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLieferumfang:\u003c\/strong\u003e Fester Gasdetektor, Benutzerhandbuch, Fernbedienung mit Batterie, Inbusschlüssel zum Entfernen der Abdeckung, 24V-Netzteil zum Anschluss an 110V-Steckdose und Verkabelung. \u003cmeta charset=\"utf-8\"\u003eWird mit einem zertifizierten Kalibrierzertifikat geliefert.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKalibrieroptionen:  \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/hydrogen-sulfide-bump-gas\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.forensicsdetectors.com\/products\/single-gas-calibration\" target=\"_blank\"\u003eKalibrierservice von Forensics Detectors\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/pages\/fd-60\"\u003eKalibrieranleitung (DIY)\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKalibrierset \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e(DIY separat erhältlich):\u003c\/strong\u003e  \u003c\/span\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/calibration-cap-fd-60\" target=\"_blank\"\u003eKalibrierkappe\u003c\/a\u003e \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/ammonia-gas-10ppm\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/carbon-dioxide-gas-1000ppm\" target=\"_blank\"\u003eKalibriergas (CO2)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/gas-regulator-fixed-flow-0-5lpm-c10\" target=\"_blank\"\u003eKalibriergasregler (C10)\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/silicone-tubing-3ft\"\u003eSchlauch\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eWeitere Artikel (separat erhältlich):\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/co2-bumpgas\" target=\"_blank\"\u003eBump-Gas (CO2)\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/hydrogen-sulfide-bump-gas\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/cap-and-pump-kit-remote-air-sampling\" target=\"_blank\"\u003eLuftprobepumpen-Kit\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/warning-alarm-buzzer-extension-alarm-for-fd-60\"\u003eAlarmverlängerung\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpezifikationen\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eKohlenstoffdioxid (CO2) Erkennung:\u003c\/strong\u003e 0 - 5000 ppm mit 1 ppm Auflösung\u003cbr\u003e\u003cstrong\u003eFehler:\u003c\/strong\u003e \u0026lt; +\/- 5% F.S.\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003e\u003cspan\u003eGassensortyp: \u003c\/span\u003e\u003c\/strong\u003eNDIR-Gassensor \u003cstrong\u003e\u003cspan\u003e\u003cbr\u003eLebensdauer des Gassensors: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u0026gt; 5 Jahre\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eEmpfohlener Kalibrierzeitraum:\u003c\/strong\u003e 12 Monate\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eExplosionsschutzklasse:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003eATEX-zertifiziert Ex d ⅡC T6 Gb\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003eSchutzart: \u003c\/strong\u003eIP66\u003cbr\u003e\u003cstrong\u003eAlarm:\u003c\/strong\u003e LED, Summer\u003cbr\u003e\u003cstrong\u003eAnsprechzeit:\u003c\/strong\u003e \u0026lt;60 Sekunden\u003cbr\u003e\u003cstrong\u003eStromversorgung:\u003c\/strong\u003e DC 24V ± 15%\u003cbr\u003e\u003cstrong\u003eLager- \/ Betriebstemperatur:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e0 °F - 122 °F\u003cstrong\u003e\u003cbr\u003eLager- \/ Betriebsfeuchtigkeit:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u0026lt;95 % r.F.\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eElektrischer Ausgang:\u003c\/strong\u003e 2 x Relais-Kontaktausgang, max. Leistung 50W pro Relais\u003cbr\u003e\u003cb\u003eKommunikation: \u003c\/b\u003e4 - 20 mA und RS485\u003cbr\u003e\u003cstrong\u003eAbmessungen:\u003c\/strong\u003e 200 mm x 180 mm x 90 mm\u003cbr\u003e\u003cstrong\u003eGewicht:\u003c\/strong\u003e 3 lbs\u003cbr\u003e\u003cstrong\u003eGewinde:\u003c\/strong\u003e G1\/2 Außengewinde, Schlauchanschlussgröße M20 x 1,5 mm\u003cbr\u003e\u003cstrong\u003eKalibrierort (USA):\u003c\/strong\u003e Los Angeles, Kalifornien, USA\u003cbr\u003e\u003cstrong\u003eKalibrierstandard (USA):\u003c\/strong\u003e USA NIST rückverfolgbare Gasquelle\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eKalibrierort (Europa):\u003c\/strong\u003e Athen, Griechenland\u003cbr\u003e\u003cstrong\u003eKalibrierstandard (Europa):\u003c\/strong\u003e Europäische NPL rückverfolgbare Gasquelle\u003cbr\u003e\u003c\/p\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":44117943025887,"sku":"FD-60-CO2-PPM","price":895.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/Image1-FD-60-CO2-PPM-Shopify.jpg?v=1769035165","url":"https:\/\/www.forensicsdetectors.com\/de\/products\/co2-monitor-usa-nist-calibration","provider":"Forensics Detectors","version":"1.0","type":"link"}