{"product_id":"professional-combustion","title":"Professional Combustion Analyzer | Monoxor | USA NIST Calibration","description":"\u003cp\u003e\u003cb\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/N35xWkynVZM\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003cbr\u003eBrand:\u003c\/b\u003e FORENSICS DETECTORS\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e FD-600-FLUE \u003cbr\u003e\u003cstrong\u003eUser Manual\u003c\/strong\u003e: \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/600_combustion_v2.0.pdf?v=1657558018\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003eBlog Article:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/blogs\/articles\/what-are-combustion-analyzers\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e⚛️ \u003cstrong\u003eUSES:\u003c\/strong\u003e \u003cstrong\u003e\"Monoxor\" equivalent\u003c\/strong\u003e. For combustion flue gas analysis in HVAC systems, appliance exhaust, check and maintenance, cracked exchange, leakage, and indoor air quality.\u003c\/li\u003e\n\u003cli\u003e🌇 \u003cstrong\u003eFEATURES:\u003c\/strong\u003e Color screen, graphing, and data logging functions. Includes waterproof hard case, water trap, particle filter, and NOx filter to reduce cross-sensitivity errors.\u003c\/li\u003e\n\u003cli\u003e🔬 \u003cstrong\u003eSENSORS:\u003c\/strong\u003e Electrochemical sensors with oxygen (O2) and carbon monoxide (CO). Calculates COAF (CO air free) and excess air (EA) for combustion analysis. Built-in micro-pump (0.5 LPM).\u003c\/li\u003e\n\u003cli\u003e💪 \u003cstrong\u003eSTRONG:\u003c\/strong\u003e Robust design with ABS and anti-slip grip rubber. Comes with an aluminum probe, a back magnet for easy mounting, and a waterproof hard case\u003c\/li\u003e\n\u003cli\u003e🕵️ \u003cstrong\u003eTRUSTWORTHY:\u003c\/strong\u003e 1-year limited warranty. Arrives with a signed and dated calibration certificate. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e\u003cstrong\u003eDetails:\u003c\/strong\u003e Forensics Detectors presents a high-quality combustion analyzer with a built-in pump and a high-quality gas sample probe. \u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eThis is the equivalent of the Bacharach Monoxor that was discontinued.\u003c\/span\u003e\u003c\/strong\u003e A workhorse for HVAC workers, contractors, plumbers, engineers, and technicians for combustion, flue gas, and exhaust gas analysis. The device is perfect for boilers, heaters, furnaces, and other natural gas or propane-burning appliances. It is also well-suited to indoor air quality, CO, and O2 analysis. The unit is packed with advanced features such as a 32-bit microprocessor, color screen, real-time graphing, and data logging functions. The display is massive and shows CO, O2, COAF (CO air-free), and EA (excess air). The detector can also be (1) an ambient detector for general air quality measurements (2) a spot detector or (3) a combustion and flue gas analyzer. Please note, that this analyzer does NOT detect flue temperature or calculate combustion efficiency and does not detect nor calculate carbon dioxide (CO2). In addition, also note that this unit is not made for automotive exhaust gases since the CO in automotive combustion engines typically exceeds 1000ppm CO and may blow out the CO sensor. For automotive exhaust applications, please see the \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/exhaust-gas-analyzer-carbon-monoxide-motorcycle-forklift-automotive\"\u003eauto exhaust gas analyzer\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e Robust, waterproof ABS hard case, model 600 analyzer with CO and O2 sensors, niobium magnet for easy mounting, point sample probe, hose assembly with 3 feet of high temp silicone tubing, water trap, particle filter, NOx filter, USB charging cable, USB charger, certified traceable calibration certificate, and a user manual.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCalibration Options:  \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/hydrogen-sulfide-bump-gas\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.forensicsdetectors.com\/products\/multigas-calibration\" target=\"_blank\"\u003eCalibration Service by Forensics Detectors\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/pages\/fd-601\"\u003eCalibration Tutorial (DIY)\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration Kit (DIY \u003cmeta charset=\"utf-8\"\u003esold separately):  \u003c\/strong\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/ammonia-gas-10ppm\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/combustion-gas-co-200-ppm-co2-50\" target=\"_blank\"\u003eCalibration Gas (Combustion Gas)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/gas-regulator-fixed-flow-0-5lpm-c10\" target=\"_blank\"\u003eCalibration Gas Regulator (C10)\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/t-piece-and-tubing\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/t-piece-and-tubing\"\u003eCalibration T-piece \u0026amp; Tubing\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/carbon-monoxide-bump-gas\" target=\"_blank\"\u003eBump Gas (CO)\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/gas-mix-bump-gas\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/n2-n2-bump-gas\" target=\"_blank\"\u003eBump Gas (N2)\u003cbr\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/gas-mix-bump-gas\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cstrong\u003eAccessories and Parts:\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/carbon-monoxide-sensor-replacement\" target=\"_blank\"\u003eGas Sensor Replacement (CO)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/oxygen-sensor-alpha\" target=\"_blank\"\u003eGas Sensor Replacement (O2)\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/oxygen-sensor-alpha\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/detector-stand-universal\" target=\"_blank\"\u003eGas Detector Stand\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/probe-stainless-steel-telescopic\"\u003eTelescopic Probe\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/silicone-tubing-3ft\"\u003eTubing (3ft)\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSensors:\u003c\/strong\u003e Electrochemical (O2 and CO)\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eOxygen (O2) Detection:\u003c\/strong\u003e 0 - 30% with 0.1% resolution\u003cbr\u003e\u003cstrong\u003eCarbon Monoxide (CO) Detection:\u003c\/strong\u003e 0 - 999 ppm with 1 ppm resolution\u003cbr\u003e\u003cstrong\u003eError:\u003c\/strong\u003e ≤ ± 5% F.S. \u003cbr\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 30 seconds\u003cbr\u003e\u003cstrong\u003eStore \/ Operating Temp:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e0°F - 122°F (for analyzer)\u003cstrong\u003e\u003cbr\u003eStore \/ Operating Humidity:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u0026lt;95%RH\u003cbr\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e DC 3.7V Li-on battery, 2000 mAh\u003cbr\u003e\u003cstrong\u003e\u003cspan\u003eGas Sensor Type: \u003c\/span\u003e\u003c\/strong\u003eElectrochemical Gas Sensor\u003cbr\u003e\u003cstrong\u003eGas Sensor Life:\u003c\/strong\u003e 2 - 3 years\u003cbr\u003e\u003cstrong\u003eRecommended Calibration Period: \u003c\/strong\u003e12 months\u003cbr\u003e\u003cstrong\u003eExplosion-Proof Grade:\u003c\/strong\u003e ATEX certified Ex ib IIC T4 Gb\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eAlarm:\u003c\/strong\u003e LED, Buzzer, and Vibration\u003cbr\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 14 oz\u003cbr\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 5.1 in × 2.6 in x 1.2 in\u003cbr\u003e\u003cstrong\u003eCharging Time:\u003c\/strong\u003e 3 hours\u003cbr\u003e\u003cstrong\u003eOperating Time:\u003c\/strong\u003e \u0026gt; 10 hours\u003cbr\u003e\u003cstrong\u003ePump Rate:\u003c\/strong\u003e 0.3 - 0.5 LPM (300 - 500 cc\/min)\u003cbr\u003e\u003cstrong\u003eCase Dimensions:\u003c\/strong\u003e 11.7 in x 8.3 in x 3.8 in (L x W x H)\u003cbr\u003e\u003cstrong\u003eProbe length:\u003c\/strong\u003e 6 in\u003cbr\u003e\u003cstrong\u003eMax Probe Flue Gas Exposure Temperature: \u003c\/strong\u003e550\u003cmeta charset=\"utf-8\"\u003e°F for 5-minute periods\u003cbr\u003e\u003cstrong\u003eCalibration Location (USA):\u003c\/strong\u003e Los Angeles, California, USA\u003cbr\u003e\u003cstrong\u003eCalibration Standard (USA):\u003c\/strong\u003e USA NIST Traceable Gas Source\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003cstrong\u003eCalibration Location (Europe):\u003c\/strong\u003e Athens, Greece\u003cbr\u003e\u003cstrong\u003eCalibration Standard (Europe):\u003c\/strong\u003e European NPL Traceable Gas Source\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":40639339659427,"sku":"FD-600-FLUE","price":495.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/Image1-FD-600-FLUE-Shopify.jpg?v=1770684832","url":"https:\/\/www.forensicsdetectors.com\/en-de\/products\/professional-combustion","provider":"Forensics Detectors","version":"1.0","type":"link"}