{"product_id":"ozone-sensor-replacement","title":"Ozone Sensor (O3) | 0 - 20 ppm |","description":"\u003cp\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel: \u003c\/b\u003eFD-O3-SENSOR\u003cbr\u003e\u003cb\u003eDatasheet:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/Eng_S4-O3-20_datasheet_1_-_Copy.pdf?v=1743716475\"\u003e\u003cspan\u003eClick Here PDF\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cspan\u003e\u003cb\u003eAvailability: \u003c\/b\u003e3 week lead time\u003cbr\u003e\u003cstrong\u003eCompatible:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/ozone-detector\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eFD-90A-O3\u003c\/a\u003e, \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/ozone-detector-analyzer-600\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eFD-600-O3\u003c\/a\u003e, \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/ozone-detector-wall\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eFD-60-O3\u003c\/a\u003e, \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/ozone-o3-meter\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eFD-90-O3\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"s1\"\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e⚛️ \u003c\/span\u003eHigh precision and long life (2 years)\u003c\/li\u003e\n\u003cli\u003e🚄 Fast response speed, fast return to zero\u003c\/li\u003e\n\u003cli\u003e🔋 Low power consumption, high sensitivity\u003c\/li\u003e\n\u003cli\u003e🔬Wide linear range, strong anti-interference ability\u003c\/li\u003e\n\u003cli\u003e💪 Excellent repeatability and stability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThese are generic O3 sensors used as the pin-to-pin replacement of the standard 4-series electrochemical sensors. It is used throughout many gas detector brands and is an excellent O3 gas sensor replacement element.\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eOur O3 sensor employs an advanced electrolytic mechanism where ozone undergoes precise electrochemical oxidation across specialized electrodes. By maintaining a controlled potential between working and reference electrodes, this sophisticated sensor enables accurate measurement of ozone levels. The generated electrical current provides a quantitative assessment of O3 concentration in various environmental and industrial monitoring applications.\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eOzone detection technologies play a critical role across diverse medical and environmental domains. From medical disinfection facilities and municipal infrastructure to atmospheric research, O3 detectors provide comprehensive gas concentration insights. These advanced sensing systems enable precise measurement, early warning mechanisms, and critical monitoring, supporting public health, environmental protection, and safety in multiple application sectors.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eInstructions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOnce replaced and installed in your gas detector or analyzer, please let it sit for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 hours\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eso the sensor can stabilize to your environment. This step is very important.\u003c\/li\u003e\n\u003cli\u003eThen undertake the appropriate zero and calibration for your specific gas detector. See your gas detector manufacturer's specific instructions.\u003c\/li\u003e\n\u003cli\u003eOnce calibrated, your gas analyzer will be ready for use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width: 99.9971%; height: 391.796px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eDetection Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003eElectrochemical Three electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eDetection Gas\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003eO3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eDetection Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e0-20 PPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eMaximum Load Concentration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e50 PPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e-600±150 nA\/PPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eZero Drift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e0~1 PPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e0.5 PPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e\u0026lt;60s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eBias Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eLoad Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e5~30Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eWorking Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e-30℃-50℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eWorking Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e15%RH to 90%RH (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e\u0026lt;±2% output signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eLong-term Stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e\u0026lt;2% signal\/month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eLinearity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003eRegression coefficient R²=0.999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eWork Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e90 to 110 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eShelf Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e12 months after delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5898px;\"\u003e\n\u003ctd style=\"width: 45.6266%; height: 19.5898px;\"\u003e\u003cstrong\u003eService Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.5861%; height: 19.5898px;\"\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"pro_t\"\u003eCross-Sensitivity Data\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"center\"\u003e\u003cstrong\u003eInterfering Gas\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth align=\"center\"\u003e\u003cstrong\u003eGas Concentration Used (ppm)\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth align=\"center\"\u003e\u003cstrong\u003eValue Displayed (ppm O3)\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003eCO\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e500\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003eSO2\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e20\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003eH2S\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e50\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e-15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003eH2\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1000\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003eNO2\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e25\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":42438997016799,"sku":"FD-O3-SENSOR","price":165.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/ozone_sensors.jpg?v=1747244882","url":"https:\/\/www.forensicsdetectors.com\/en-es\/products\/ozone-sensor-replacement","provider":"Forensics Detectors","version":"1.0","type":"link"}