{"product_id":"oxygen-analyzer-welding","title":"Oxygen Analyzer | Leak Purge \u0026 Weld Monitor (100ppm)","description":"\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/MqOxmKZxsGA?si=NGV9gZdp08Bqrn1Q\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan class=\"s1\"\u003eBrand: \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003eFORENSICS DETECTORS\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"s1\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003eFD-600-O2-LEAK\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eData Logging:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/pages\/fd-600\" rel=\"noopener\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"s2\"\u003e\u003cbr\u003e\u003cstrong\u003eUser Manual:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s2\"\u003e\u003cspan\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/600_Manual_v7.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eClick Here\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eBlog Article:\u003c\/strong\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/blogs\/articles\/how-are-oxygen-analyzers-used-in-welding\" target=\"_blank\"\u003e Click Here\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e🎆\u003cstrong\u003e USES:\u003c\/strong\u003e Used for precise oxygen depletion analysis, welding purge analysis, and argon or nitrogen leak detection: High-quality electrochemical oxygen sensor. Comes FACTORY-CALIBRATED.\u003c\/li\u003e\n\u003cli\u003e🌈 \u003cstrong\u003eCOLOR DISPLAY:\u003c\/strong\u003e Color screen and graph functions allow for easy and intuitive operation.\u003c\/li\u003e\n\u003cli\u003e📲\u003cstrong\u003e DATA LOGGING:\u003c\/strong\u003e USB recharging and real-time data acquisition. Arrives with silicone tubing, a stainless probe, and a filter.\u003c\/li\u003e\n\u003cli\u003e💪 \u003cstrong\u003eSTRONG:\u003c\/strong\u003e Robust design constructed with high-strength ABS and anti-slip grip rubber. Water, dust, and explosion resistance.\u003c\/li\u003e\n\u003cli\u003e🕵️\u003cstrong\u003e TRUSTWORTHY:\u003c\/strong\u003e 1-year limited warranty. Arrives with a signed and dated calibration certificate. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eDetails:\u003c\/b\u003e You don't need to break the bank for a quality 0.01% (100 ppm) resolution oxygen detector for O2 depletion analysis for TIG or MIG welding. The FORENSICS oxygen analyzer is an excellent option for those that would like to confirm low oxygen content in inert environments. The device \u003cspan\u003eaccurately monitors oxygen levels while using inert \u003c\/span\u003egas\u003cspan\u003e to purge stainless steel, titanium, and other reactive metals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhen welding, the objective is to remove as much oxygen as possible.\u003c\/li\u003e\n\u003cli\u003eThe best welding results occur when there is no oxidation, hence the need for minimal oxygen levels.\u003c\/li\u003e\n\u003cli\u003eWeld oxidation degrades the mechanical properties of a pipe and reduces its resistance to corrosion.\u003c\/li\u003e\n\u003cli\u003eTo reduce this oxidation, the oxygen content must be dramatically lowered.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eThe oxygen g\u003c\/span\u003eas analyzer measures the oxygen content in the weld chamber down to 0.01% (100 ppm). Based on our industrial analyzer platform, the built-in pump is easy to use, light, and very portable. Simply insert the probe into the tubing with the filter and onto the analyzer barb. The user has full pump control, withdrawing small or large quantities of air with the built-in pump. The analyzer has a color screen, large digits, and on-screen real-time graphing. The detector is built using an advanced electrochemical oxygen sensor. The internal 32-bit microprocessor allows for user calibration, ON\/OFF flow, and test control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003cspan\u003e O2 analyzer and magnet back, user manual, certified calibration certificate, USB charging cable, charger, 1 x 3inch stainless needle probe, particle filter, and 3 ft silicone tubing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCalibration Options:  \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/hydrogen-sulfide-bump-gas\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/single-gas-calibration\" target=\"_blank\"\u003eCalibration Service by Forensics Detectors\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/pages\/fd-601\"\u003eCalibration Tutorial (DIY)\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration Kit Items \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e(DIY sold separately): \u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/t-piece-and-tubing\" target=\"_blank\"\u003eCalibration T-piece \u0026amp; Tubing\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/ammonia-gas-10ppm\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/nitrogen-gas-99-999\" target=\"_blank\"\u003eCalibration Gas (N2)\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/oxygen-sensor-alpha\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/gas-regulator-mini-flowmeter\" target=\"_blank\"\u003eCalibration Gas Regulator (C10)\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/n2-n2-bump-gas\"\u003eBump Gas (N2)\u003c\/a\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/ammonia-gas-10ppm\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Accessories \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e(sold separately):\u003c\/strong\u003e  \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/oxygen-sensor-alpha\" target=\"_blank\"\u003eGas Sensor Replacement (O2)\u003cbr\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/carry-case-waterproof\" target=\"_blank\"\u003eGas Detector Waterproof Case\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/detector-stand-universal\" target=\"_blank\"\u003eGas Detector Stand\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/3-inch-probe\"\u003eAir Gas Sample Probe\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/silicone-tubing-3ft\"\u003eTubing\u003c\/a\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOxygen (O2) Detection:\u003c\/strong\u003e 0 - 30% with 0.01% resolution\u003cbr\u003e\u003cstrong\u003eError:\u003c\/strong\u003e ≤ ± 1%\u003cbr\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 30 seconds\u003cbr\u003e\u003cstrong\u003eStore \/ Operating Temp:\u003c\/strong\u003e\u003cspan\u003e 0°F - 122°F\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eStore \/ Operating Humidity:\u003c\/strong\u003e\u003cspan\u003e \u0026lt;95%RH\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eBattery:\u003c\/strong\u003e DC 3.7V Li-on battery, 3200 mAh\u003cbr\u003e\u003cstrong\u003eGas Sensor Type:\u003c\/strong\u003e\u003cspan\u003e Electrochemical Gas Sensor\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eGas Sensor Life:\u003c\/strong\u003e 2 - 3 years\u003cbr\u003e\u003cstrong\u003eRecommended Calibration Period: \u003c\/strong\u003e12 months\u003cbr\u003e\u003cstrong\u003eExplosion-Proof Grade:\u003c\/strong\u003e ATEX certified Ex ib IIC T4 Gb\u003cbr\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 14 oz\u003cbr\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 5.1 in × 2.6 in x 1.2 in\u003cbr\u003e\u003cstrong\u003eCharge Time:\u003c\/strong\u003e 4 hours\u003cbr\u003e\u003cstrong\u003eOperating Time:\u003c\/strong\u003e \u0026gt; 10 hours\u003cbr\u003e\u003cstrong\u003ePump Rate:\u003c\/strong\u003e 0.1 - 0.3 LPM (100 - 300 cc\/min)\u003cbr\u003e\u003cstrong\u003eAlarm:\u003c\/strong\u003e LED\u003cbr\u003e\u003cstrong\u003eCalibration Location (USA):\u003c\/strong\u003e Los Angeles, California, USA\u003cbr\u003e\u003cstrong\u003eCalibration Standard (USA):\u003c\/strong\u003e USA NIST Traceable Gas Source\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eCalibration Location (Europe):\u003c\/strong\u003e Athens, Greece\u003cbr\u003e\u003cstrong\u003eCalibration Standard (Europe):\u003c\/strong\u003e European NPL Traceable Gas Source\u003cbr\u003e\u003c\/p\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":32071076577324,"sku":"FD-600-O2-LEAK","price":595.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/Image1-FD-600-O2-LEAK-Shopify.jpg?v=1756217320","url":"https:\/\/www.forensicsdetectors.com\/en-fr\/products\/oxygen-analyzer-welding","provider":"Forensics Detectors","version":"1.0","type":"link"}