{"title":"Probes","description":"\u003cp\u003eProbes are used to draw in the sample gas and used in conjunction with a gas analyzer that has a pump to create suction (negative pressure). Probes range in size and characteristics. We offer very small needle probes for headspace analysis, telescopic probes for inspectors, small stainless steel probes for leak detection, and high-temperature probes for combustion analysis. Be attentive as \u003ca href=\"https:\/\/www.forensicsdetectors.com\/collections\/gas-filters\"\u003egas filters \u003c\/a\u003emay be needed for your application to condition the gas before entering the gas analyzer. See our\u003ca href=\"https:\/\/youtube.com\/playlist?list=PLSc0GeHvOR7tdMjO7MJjLYBbaGgDMZZwY\u0026amp;si=HN7j6SpPnoBL7Iox\" target=\"_blank\" rel=\"noopener\"\u003e YouTube playlist\u003c\/a\u003e of our Probes.\u003c\/p\u003e","products":[{"product_id":"gas-sampling-pump","title":"Gas Sampling Pump \u0026 Probe","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/jLjUewpKXpc?si=QjcviCuH1yAfvmPw\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eBrand:\u003c\/b\u003e FORENSICS DETECTORS\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel: \u003c\/b\u003eFD-PUMP\u003c\/span\u003e\u003cspan class=\"s2\"\u003e\u003cbr\u003e\u003cstrong\u003eUser Manual PUMP:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/Manual_pump.pdf?100\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003eQuick Start Guide with Detector \u0026amp; Pump:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/Quick_start_guide.pdf?100\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e🎆 \u003cstrong\u003eUSES:\u003c\/strong\u003e Hand-held electric pump (0.5 LPM, 500 cc\/min) ideal for point and remote gas sampling (up to 50 feet) for air and toxic gas.\u003c\/li\u003e\n\u003cli\u003e🏭 \u003cstrong\u003eDETECT:\u003c\/strong\u003e Compatible with most diffusive type gas detectors. Gas tube plugs into detector's calibration cap.\u003c\/li\u003e\n\u003cli\u003e🏹 \u003cstrong\u003eFEATURES:\u003c\/strong\u003e Operates at a convenient 0.5L PM flow rate with temperature, time, date, and pump power reading on a high-resolution LCD screen with a backlight.\u003c\/li\u003e\n\u003cli\u003e💪 \u003cstrong\u003eSTRONG:\u003c\/strong\u003e Strong ABS construction. Comes with all accessories, USB cable, probe, pump, and standard 3 feet of 1\/8 inch ID silicone tubing.\u003c\/li\u003e\n\u003cli\u003e🕵️ \u003cstrong\u003eTRUSTWORTHY:\u003c\/strong\u003e ** 1-year limited warranty ** \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eDetails:\u003c\/b\u003e The GAS SAMPLING PUMP by FORENSICS is used for sampling gas with a detector or for filling a gas sample bag. Samples of particulates, vapors, and gases. Can draw samples from up to 50 ft (15 m) away. Quickly convert diffusion instruments to remote gas or point sampling. Gas input is measured through a stainless steel probe (8.6 inches in length). Gas output is a male 3\/16\" tube barb connector that connects to \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/silicone-tubing-3ft\"\u003estandard tubing ID (1\/8\" diameter)\u003c\/a\u003e. Advanced features include temperature detection, time, date, and backlight, a high-resolution LCD. The power and pump resistance are also clearly indicated, so the user has insight into the pump load. Ideal for point sampling in \"toxic gas\" environments to avoid harmful inhalation and exposure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003cspan\u003e Sampling gas pump\u003c\/span\u003e, English manual, mini USB charging cable, stainless probe, and 3 ft silicone tubing.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFlow Rate:\u003c\/strong\u003e 0.5 LPM (500 cc\/min)\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eStore \/ Operating Temp:\u003c\/strong\u003e\u003cspan\u003e 0°F - 122°F\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eStore \/ Operating Humidity:\u003c\/strong\u003e\u003cspan\u003e \u0026lt;95%RH\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eNoise:\u003c\/strong\u003e \u0026lt; 60 dB\u003cbr\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 140 g (with battery)\u003cbr\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 65 mm x 30 mm x 225 mm\u003cbr\u003e\u003cstrong\u003eVoltage: \u003c\/strong\u003eDC 3.7V Li battery 1800 mAh\u003cstrong\u003e\u003cbr\u003eProbe Thread:\u003c\/strong\u003e M6 x 0.75 mm\u003cbr\u003e\u003cstrong\u003eBarb Outer Diameter: \u003c\/strong\u003e3\/16\" (4.78 mm)\u003c\/p\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":30700796903468,"sku":"FD-PUMP","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/Image1-FD-PUMP-Shopify.jpg?v=1750662006"},{"product_id":"probe-stainless-steel-telescopic","title":"Air Gas Sample Probe | Telescopic  | 4 feet","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eBrand:\u003c\/b\u003e FORENSICS DETECTORS\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eFD-TELESCOPIC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"s1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCompatible Detectors:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eFD-600 (all versions), \u003ca href=\"https:\/\/www.forensicsdetectors.com\/collections\/inert-gas-analyzers\" target=\"_blank\"\u003eFD-311 (all versions)\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"uk-list\"\u003e\n\u003cli\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e⚛️  \u003c\/span\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e  \u003cmeta charset=\"utf-8\"\u003eThe probe compacts down to 1 foot but extends beyond 4 feet. It's the perfect solution to sampling air in those hard-to-reach locations - great for inspectors and other workers. This is the standard probe that comes with most of our FD-600 models such as the \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/multigas-detector-600\" target=\"_blank\"\u003e4GAS version\u003c\/a\u003e. The probe comes with tubing to fit the barb of the FD-600 or FD-311 inlet port. Please note that this product should be able to fit any analyzer with a built-in pump due to the flexibility of the silicon tubing attachment. The tube line will fit barbs with outer diameters from 3 to 6 mm.\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e📶  How does it work?\u003c\/strong\u003e Extend the probe. Point and sample. Connect the tubing to the bard of the analyzer. The detector will suck the air and will obtain an air sample from the endpoint of the telescopic probe.  \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e👫  \u003cstrong\u003eInstructions: \u003c\/strong\u003eHold the probe. \u003cmeta charset=\"utf-8\"\u003eThe probe tip is where the air will be drawn through the probe assembly to the outlet barb. Note, that there is no pump in this unit. Therefore, suction must be produced by the detector\/analyzer with a built-in pump.  \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDO NOT\u003c\/span\u003e \u003c\/strong\u003euse this probe for high-temperature applications such as combustion or exhaust analysis.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/emojipedia.org\/symbols\/\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/emojipedia.org\/symbols\/\"\u003e🔣\u003c\/a\u003e  \u003cstrong\u003eSpecifications\u003c\/strong\u003e:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e stainless steel probe, and ABS grip handle\u003c\/li\u003e\n\u003cli\u003eComes with flexible tubing (ID 2 mm, OD 5 mm) with a short 2-inch silicon tubing coupler \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-mce-fragment=\"1\"\u003e(ID 3 mm, OD 6 mm).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003eMax operating temp = 120F\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":34962522144931,"sku":"FD-TELESCOPIC","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/products\/ProbePlain.jpg?v=1641632646"},{"product_id":"breath-kit-probe-filter-tubing","title":"Generic Gas Filter \u0026 Probe Kit","description":"\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/HoSZ3i4sMzI?si=Fofe-QTRUYOmsAxn\" height=\"315\" width=\"560\" allowfullscreen=\"\" referrerpolicy=\"strict-origin-when-cross-origin\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eBrand:\u003c\/b\u003e FORENSICS DETECTORS\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eFD-GENERIC-KIT\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis generic gas filter is used for applications that require filtration of particles and humidity. These applications include welding, weld purge, incubator, and breath analysis. When sampling volatile gas mixtures, this filter removes aggressive gases that may poison the sensors. The kit components include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 x stainless steel probes: 50 mm length, 2 mm diameter, stainless steel luer lock connectors for easy on and off.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eHigh temperature and flexible silicone tubing: ID 3 mm and OD 6 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eFilter element with media: activated charcoal (gas adsorption list \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/Activated_Carbon_Adsorption_List.pdf?v=1607146508\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/Activated_Carbon_Adsorption_List.pdf?v=1607146508\"\u003ehere\u003c\/a\u003e\u003cspan\u003e) and silica gel to remove moisture\/humidity, comes with barb for easy on\/off.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe total length of the assembly is about 2 feet.\u003c\/p\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":34962965332131,"sku":"FD-FILTER+2INCH","price":60.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/products\/breath2xplain.jpg?v=1641631454"},{"product_id":"combustion-line-water-trap-filter-and-tubing","title":"Combustion \u0026 Moisture Line Filter Kit","description":"\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/HoSZ3i4sMzI?si=Fofe-QTRUYOmsAxn\" height=\"315\" width=\"560\" allowfullscreen=\"\" referrerpolicy=\"strict-origin-when-cross-origin\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eBrand:\u003c\/b\u003e FORENSICS DETECTORS\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eFD-FLUE-KIT\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis combustion line kit is compatible with the \u003ca href=\"https:\/\/www.forensicsdetectors.com\/collections\/combustion-analyzers-1\" target=\"_blank\"\u003eFD-4A, FD-4S, and FD-600 combustion analyzers\u003c\/a\u003e. It is also can be used in gas sample filtering of volatile gases and of gas streams that have high humidity and condensate. The kit includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh temperature and flexible silicone tubing: 3 mm ID and 6 mm OD\u003c\/li\u003e\n\u003cli\u003eWater trap and magnetic particle filter (to trap any metal particles and trap condensate and larger particles also)\u003c\/li\u003e\n\u003cli\u003eFilter media consists of a special blend to eliminate moisture, humidity, and acidic gasses. The filter media is composed of activated charcoal, silica gel, activated alumina, and potassium permanganate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe length of the assembly is about 2 feet.\u003c\/p\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":34963942768803,"sku":"FD-COMBUSTION-KIT","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/products\/lineplain.jpg?v=1641623046"},{"product_id":"3-inch-probe","title":"Air Gas Sample Probe | Needle | 3 inches","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eBrand:\u003c\/b\u003e FORENSICS DETECTORS\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eFD-PROBE-3INCH\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong data-mce-fragment=\"1\"\u003eCompatible Detectors:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eFD-600 \u0026amp; FD-600M (all versions), \u003cmeta charset=\"utf-8\"\u003eFD-311 (all versions)\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"uk-list\"\u003e\n\u003cli\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e⚛️  \u003c\/span\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003eThis 3-inch probe can be used in various gas and air quality sampling applications where a small form factor and probe gauge are desired. Perfect for gas leak detection applications. This probe comes standard in our \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/oxygen-analyzer-welding\" target=\"_blank\"\u003eO2 weld analyzer\u003c\/a\u003e and \u003ca href=\"https:\/\/www.forensicsdetectors.com\/collections\/inert-gas-analyzers\" target=\"_blank\"\u003einert gas leak detectors.\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e📶  How does it work?\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003eY\u003cmeta charset=\"utf-8\"\u003eou can connect the tubing directly to a detector with a micro-pump, such as our FD-600 analyzers. When fastened to a pump inlet port, it can serve as a sampling probe. Examples of applications include breath, food, leak detection probes, incubators, and small confined spaces. You can also cut the tubing very short and attach it to your pump analyzer barb (FD-600, FD-311, or FD-600M) for one-hand point sampling (see images).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e👫  \u003cstrong\u003eInstructions: \u003c\/strong\u003eAs shown in the image, hold the probe. The probe tip will draw the air through the tubing to your detector. The tubing on the other end must be connected to a pump or analyzer with a built-in pump.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/emojipedia.org\/symbols\/\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/emojipedia.org\/symbols\/\"\u003e🔣\u003c\/a\u003e  \u003cstrong\u003eSpecifications\u003c\/strong\u003e:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e1 x stainless steel probe (75 mm in length and 2 mm in diameter)\u003c\/li\u003e\n\u003cli\u003eStainless steel Luer lock connectors for easy on and easy off\u003c\/li\u003e\n\u003cli\u003eHigh temperature and flexible silicone tubing (ID 3 mm, OD 6 mm)\u003c\/li\u003e\n\u003cli\u003eThe total length of the assembly is about 3 feet.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":40143352922275,"sku":"FD-PROBE-3INCH","price":29.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/products\/IMG_3440x_84b22364-98b0-4232-850d-da7fec9c3110.jpg?v=1641632773"},{"product_id":"probe-pistol-style-6-inches","title":"Air Gas Sample Probe | Pistol Grip | 6 inches","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eBrand:\u003c\/b\u003e FORENSICS DETECTORS\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eFD-PROBE-PISTOL\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong data-mce-fragment=\"1\"\u003eCompatible Detectors:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eFD-600 (all versions), \u003cmeta charset=\"utf-8\"\u003eFD-311 (all versions)\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"uk-list\"\u003e\n\u003cli\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e⚛️  \u003c\/span\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003eThis is a pistol-style, 6-inch probe that is ideal for \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/professional-combustion\" target=\"_blank\"\u003ecombustion\u003c\/a\u003e, indoor air quality, duct, vent air, and leak analysis. Feels great to use with a soft touch rubber grip. The probe tip is replaceable and the unit comes with a 4 mm outlet barb that allows for easy tubing connections.\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e📶  How does it work?\u003c\/strong\u003e The air sample pistol probe is used by placing it in the desired sampling direction.  \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e👫  \u003cstrong\u003eInstructions: \u003c\/strong\u003e Connect the probe to a silicone tube line. Connect it to your analyzer and or in-line filter arrangement. The probe tip is where the air will be drawn through the probe assembly to the outlet barb. Note, that there is no pump in this unit. Therefore, suction must be produced by an inline pump or by a detector\/analyzer with a built-in pump.  \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca data-mce-fragment=\"1\" href=\"https:\/\/emojipedia.org\/symbols\/\" data-mce-href=\"https:\/\/emojipedia.org\/symbols\/\"\u003e🔣\u003c\/a\u003e  \u003cstrong\u003eSpecifications\u003c\/strong\u003e:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e cast aluminum body, stainless steel tip, and rubber grip\u003c\/li\u003e\n\u003cli\u003eComes with high temperature and flexible silicone tubing (ID 3 mm, OD 6 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":40144986800291,"sku":"FD-PROBE-PISTOL","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/products\/IMG_3321x_c485a66e-08a2-455d-b2a9-640af55cb244.jpg?v=1641632754"},{"product_id":"air-gas-sample-probe-needle-1-inch","title":"Air Gas Probe with Filter | Needle | 1 inch","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eBrand:\u003c\/b\u003e FORENSICS DETECTORS\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eFD-PROBE-1INCH\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong data-mce-fragment=\"1\"\u003eCompatible Detectors:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eFD-600 (all versions), \u003cmeta charset=\"utf-8\"\u003eFD-311 (all versions), \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/gas-sampling-pump\" target=\"_blank\"\u003eFD-PUMP\u003c\/a\u003e \u0026amp; Detector combo\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"uk-list\"\u003e\n\u003cli\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e⚛️  \u003c\/span\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003eThis is a generic 1-inch probe that can be used in a variety of applications such as \u003ca href=\"https:\/\/www.forensicsdetectors.com\/collections\/speciality-applications\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eheadspace analysis\u003c\/a\u003e and R\u0026amp;D experiments. It is excellent for gas sampling isolation - to find a small leak.\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e📶  How does it work?\u003c\/strong\u003e Y\u003cmeta charset=\"utf-8\"\u003eou can connect the tubing directly to a detector with a micro-pump, such as our FD-600 analyzers. When fastened to a pump inlet port, it can serve as a sampling probe. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e👫  \u003cstrong\u003eInstructions: \u003c\/strong\u003eAs shown in the image, hold the probe. The probe tip is where the air will be drawn through the tubing to your detector. The tubing on the other end must be connected to a pump or analyzer with a built-in pump.  \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/emojipedia.org\/symbols\/\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/emojipedia.org\/symbols\/\"\u003e🔣\u003c\/a\u003e  \u003cstrong\u003eSpecifications\u003c\/strong\u003e:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 22G 1-inch syringe needle with Luer lock\u003c\/li\u003e\n\u003cli\u003e1 x Luer lock to barb connector\u003c\/li\u003e\n\u003cli\u003e1 x Polyethersulfone Membrane (PES) microporous filter\u003c\/li\u003e\n\u003cli\u003e1 x 8 inches of high temperature and flexible silicone tubing (ID 3 mm, OD 5 mm)\u003c\/li\u003e\n\u003cli\u003eTotal length of the assembly is about 1 foot.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":40155857387683,"sku":"FD-PROBE-1INCH","price":20.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/products\/Frontneedle.jpg?v=1641632875"},{"product_id":"gas-probe-1-foot","title":"Air Gas Sample Probe | 1 foot","description":"\u003cp\u003e\u003cb\u003eBrand:\u003c\/b\u003e FORENSICS DETECTORS\u003cbr\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eFD-PROBE-1FT\u003cbr\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCompatible Detectors:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eFD-600 (all versions), \u003cmeta charset=\"utf-8\"\u003eFD-311 (all versions)\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"uk-list\"\u003e\n\u003cli\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e⚛️  \u003c\/span\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cspan\u003e \u003cmeta charset=\"utf-8\"\u003eThis probe is the companion to our FD-600 and FD-311 analyzers. This is a high-quality 1-foot length probe. It's the perfect solution for sampling air for inspectors and safety officers or technicians. The probe comes with tubing to fit the barb of the FD-600 or FD-311 inlet port. Please note that this product should be able to fit any analyzer with a built-in pump due to the flexibility of the silicon tubing attachment. The tube line will fit barbs with outer diameters from 3 to 6 mm.\u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e📶  How does it work?\u003c\/strong\u003e The air sample probe is used by directing toward the desired sampling direction.  \u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e👫  \u003cstrong\u003eInstructions: \u003c\/strong\u003eAs shown in the image, hold the probe. The probe tip is where the air will be drawn through the probe assembly to the outlet barb. Note, that there is no pump in this unit. Therefore, suction must be produced by an inline pump or by a detector\/analyzer with a built-in pump.  \u003cbr\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/emojipedia.org\/symbols\/\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/emojipedia.org\/symbols\/\"\u003e🔣\u003c\/a\u003e  \u003cstrong\u003eSpecifications\u003c\/strong\u003e:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003eThe probe is made of aluminum (handle) and the metal probe is made of stainless steel and comes with a male barb of 4mm outer diameter.\u003c\/li\u003e\n\u003cli\u003eComes with high temperature and flexible silicone tubing (ID 3 mm, OD 6 mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":43085202817247,"sku":"FD-PROBE-1FT","price":59.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/products\/1ftProbeFront.jpg?v=1653684952"},{"product_id":"air-gas-sample-probe-with-hood-telescopic-4-feet","title":"Hood Air Gas Sample Probe | Telescopic  | 4 feet","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eBrand:\u003c\/b\u003e FORENSICS DETECTORS\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eFD-TELESCOPIC-HOOD\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"s1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCompatible Detectors:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eFD-600 (all versions), \u003ca href=\"https:\/\/www.forensicsdetectors.com\/collections\/inert-gas-analyzers\" target=\"_blank\"\u003eFD-311 (all versions)\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"uk-list\"\u003e\n\u003cli\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e⚛️  \u003c\/span\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e  This is a special hooded air gas probe that allows the efficient capture of low concentrations of gas for leak detection. The probe compacts down to 1 foot but extends beyond 4 feet. It is the same as our \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/probe-stainless-steel-telescopic\"\u003e4ft telescopic probe\u003c\/a\u003e, but this version has a hooded end. It's the perfect solution for hydrogen, argon, helium, CO2, nitrogen, methane, combustibles, and many other gases typically used to be detected for high-sensitivity gas leak detection. The probe comes with tubing to fit the barb of the FD-600 or FD-311 inlet port. Please note that this product should be able to fit any analyzer with a built-in pump due to the flexibility of the silicon tubing attachment. The tube line will fit barbs with outer diameters from 3 to 6 mm.\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e📶  How does it work?\u003c\/strong\u003e Extend the probe. Point and shoot. Connect the tubing to the bard of the analyzer. The detector will suck the air and will obtain an air sample from the endpoint of the telescopic probe.  \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e👫  \u003cstrong\u003eInstructions: \u003c\/strong\u003eAs shown in the image, hold the probe. \u003cmeta charset=\"utf-8\"\u003eThe probe tip is where the air will be drawn through the probe assembly to the outlet barb. Note, that there is no pump in this unit. Therefore, suction must be produced by the detector\/analyzer with a built-in pump.  \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDO NOT\u003c\/span\u003e use this probe for combustion high-temperature applications.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca data-mce-fragment=\"1\" href=\"https:\/\/emojipedia.org\/symbols\/\"\u003e🔣\u003c\/a\u003e  \u003cstrong\u003eSpecifications\u003c\/strong\u003e:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e stainless steel probe, ABS grip handle and rubber hood.\u003c\/li\u003e\n\u003cli\u003eComes with high-temperature and flexible tubing (ID 2 mm, OD 5 mm) with a short 2-inch silicon tubing coupler \u003cmeta charset=\"utf-8\"\u003e \u003cspan data-mce-fragment=\"1\"\u003e(ID 3 mm, OD 6 mm).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe hood is 2 inches in width and 2.6 inches in depth and is made of silicone material.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":43860703740127,"sku":"FD-TELESCOPIC-HOOD","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/Hood_Image2.jpg?v=1771106825"},{"product_id":"flue-gas-cooler","title":"Gas Sample Cooler | High Temp Gas Conditioner","description":"\u003cp\u003e\u003cb\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/71fDq9FzyBI?si=eaYmcTGw9vfTMwN7\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eBrand:\u003c\/b\u003e FORENSICS DETECTORS\u003cbr\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eFD-COOLER\u003cbr\u003e\u003cstrong\u003eCompatible Detectors:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eFD-600 (all versions), \u003cmeta charset=\"utf-8\"\u003eFD-600M (all versions), \u003cmeta charset=\"utf-8\"\u003eFD-311 (all versions), FD-PUMP, FD-311 \u003cmeta charset=\"utf-8\"\u003e(all versions)\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e🎆  \u003c\/span\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cspan\u003e This is a special Gas Cooler and High-Temperature Gas Conditioning system made for high-temperature gas sampled from flue gas, exhaust gas, ovens, kilns, and other combustion processes.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e\u003cmeta charset=\"utf-8\"\u003e⚛️  MAX Temperature:\u003c\/strong\u003e The unit has a built-in cooling system that cools and conditions the air sample to prevent any high-temperature damage to your gas detector.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e🏭  \u003cstrong\u003eUses:\u003c\/strong\u003e Sampling very high-temperature gas streams such as those working with commercial boilers, flue gases, exhausts, ovens, kilns, and high-temperature manufacturing processes. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e🕵️  \u003cstrong\u003eCompatability:\u003c\/strong\u003e This gas cooling system is the perfect companion for any analyzer with a built-in pump such as the Forensics Detectors\u003c\/span\u003e FD-600 and FD-311 analyzers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDetails:\u003c\/strong\u003e\u003cspan\u003e The hot gas is probed with the 1-foot metal probe. The suction from the analyzer (not included) draws the gas through the water trap. Due to the sudden temperature change, condensation will occur and be trapped in the unit. We also recommend a external water trap from the outlet before entering the gas detector, just in case to catch any residual condensation. If your detector does not include a built-in pump, you will need an external pump to create a suction or vacuum and draw the gas sample through the system. In this case, we recommend \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/gas-sampling-pump\" target=\"_blank\"\u003eFD-PUMP\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstructions: \u003c\/strong\u003e\u003cspan\u003eTurn on the Fan. Ensure all connections are tight and the water trap is empty. Connect the gas analyzer and ensure the gas analyzer pump is ON. Again, I repeat, your gas detector or analyzer must have a pump and draw the air to the sensor which will move the hot air through the cooler. Then, ensure the DRAIN plug is blocked. This is only used to drain the condenser when testing has been completed, or when you see that the water level in the cooler is full (water will be released through the outlet). Turn on the power. Set the temperature to 21 °C, the recommended outlet temperature. Once all is confirmed OK, place your probe in the high-temperature gas stream for testing. Take your measurement. Be aware that many components will get skin-burn hot, including the metal probe, so operate this system and the probe with \u003ca href=\"https:\/\/www.amazon.com\/Resistant-Grilling-Silicone-Non-Slip-Barbecue\/dp\/B07YTVMRV4\"\u003ehigh-temperature protective PPE gloves.\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded: \u003c\/strong\u003e\u003cspan\u003eThe system comprises a 1-foot gas sampling metal probe, 3ft silicone tubing, high-temperature silicone tubing and a fan-cooled radiator.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e115\/230 VAC 50\/60 HZ\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 60W\u003cbr\u003e\u003cstrong\u003eWorking Temperature:\u003c\/strong\u003e \u003cbr\u003eMAX Gas Temp Input: 600F (315C) for 4 minutes\u003cbr\u003eMAX Gas Temp Input: 500F (260C) for 7 minutes\u003cbr\u003eMAX Gas Temp Input: 400F (204C) for 10 minutes\u003cbr\u003eMAX Gas Temp Input: 300F (150C) for 15 minutes\u003cbr\u003eMAX Gas Temp Input: up to 200F (95C) continuous\u003cbr\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 5lb\u003cbr\u003e\u003cstrong\u003eRequired Flow:\u003c\/strong\u003e 0.3-0.7 LPM\u003cbr\u003e\u003cstrong\u003eBarb OD:\u003c\/strong\u003e 3mm (input and output)\u003cbr\u003e\u003cstrong\u003eProbe:\u003c\/strong\u003e 1-foot length with 3ft silicone tubing\u003cbr\u003e\u003cstrong\u003eCase Dimensions:\u003c\/strong\u003e Length 11.7 inches, Width 8.3 inches, Height 3.8 inches. \u003c\/p\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":43948501500127,"sku":"FD-COOLER","price":695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/main_01233696-c4d5-4cdb-9e36-d9edca3e6fc0.jpg?v=1751833321"},{"product_id":"water-trap-filter","title":"Water Trap Filter","description":"\u003cp\u003ea\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/HoSZ3i4sMzI?si=Fofe-QTRUYOmsAxn\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eBrand:\u003c\/b\u003e FORENSICS DETECTORS\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eFD-FLUE-WATERTRAP\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cstrong\u003eCompatible Detectors:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/collections\/combustion-analyzers-1\"\u003eAll Combustion Analyzers\u003c\/a\u003e and \u003ca href=\"https:\/\/www.forensicsdetectors.com\/collections\/exhaust-gas-analyzers\"\u003eExhaust Gas Analyzers\u003c\/a\u003e\u003cspan\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong data-mce-fragment=\"1\"\u003eBlog Article:\u003c\/strong\u003e \u003ca data-mce-fragment=\"1\" href=\"https:\/\/www.forensicsdetectors.com\/blogs\/articles\/best-nitrogen-gas-detector-for-n2-leaks\" data-mce-href=\"https:\/\/www.forensicsdetectors.com\/blogs\/articles\/best-nitrogen-gas-detector-for-n2-leaks\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e⚛️  \u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDescription:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eThis water trap filter is the standard water trap used in the Forensics Detectors combustion filter line kit that comes with all our combustion analyzers. It can be used within an in-line sample tubing arrangement to trap condensate from your gas sample line. The water trap has a magnetic particle filter with a coarse regular particle filter mesh to catch any spurious \"junk\" as flue gas can get very dirty with a variety of debris and particulate. The top is a detachable Screw Cover to Discharge Water Condensate.\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e📶  How does it work? \u003c\/strong\u003eThe water trap is designed to remove water vapor and condensation from gas streams before they can reach the detector or analyzer. When a hot and moist gas sample exists, it is drawn through the gas line and quickly cools which changes the dew point and creates condensate (water). Before any filtering, the condensate must be trapped so it does not proceed further in the gas sample line to minimize clogging, blocking, or water damage. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"uk-list\"\u003e\n\u003cli\u003e\n\u003ca data-mce-fragment=\"1\" href=\"https:\/\/emojipedia.org\/symbols\/\" data-mce-href=\"https:\/\/emojipedia.org\/symbols\/\"\u003e🔣\u003c\/a\u003e  \u003cstrong\u003eSpecifications\u003c\/strong\u003e:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 2.1 in x 1.8 in x \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e1.3\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e in\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e1\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e oz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eBarb Length:\u003c\/strong\u003e 0.6 inches\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003eBarb Outer Diameter:\u003c\/strong\u003e 0.25 inches\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":44134449742047,"sku":"FD-FLUE-WATERTRAP","price":25.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/watertrapfrontoriginal.jpg?v=1721756594"},{"product_id":"alligator-probe-for-exhaust-pipes-6-inches","title":"Alligator Probe for Exhaust Pipes | 6 inches","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eBrand:\u003c\/b\u003e FORENSICS DETECTORS\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003c\/b\u003eFD-PROBE-EXHAUSTPROBE\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong data-mce-fragment=\"1\"\u003eCompatible Detectors:\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003eFD-600 \u0026amp; FD-600M (all versions), \u003cmeta charset=\"utf-8\"\u003eFD-311 (all versions)\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"uk-list\"\u003e\n\u003cli\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e⚛️  \u003c\/span\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e This 6-inch probe with an alligator clip to attach to an exhaust pipe to undertake exhaust gas analysis.\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cstrong\u003e📶  How does it work?\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003eY\u003cmeta charset=\"utf-8\"\u003eou can connect the alligator clip directly to an exhaust pipe. The tube will draw an exhaust gas sample, which will be taken to the attached exhaust gas analyzer.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan data-mce-fragment=\"1\"\u003e👫  \u003cstrong\u003eInstructions: \u003c\/strong\u003eAs shown in the image, hold the probe. The probe tip will draw the air through the tubing to your detector. The tubing on the other end must be connected to the tubing with the appropriate filters and water trap and then directed to your exhaust gas analyzer. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/emojipedia.org\/symbols\/\" data-mce-fragment=\"1\" data-mce-href=\"https:\/\/emojipedia.org\/symbols\/\"\u003e🔣\u003c\/a\u003e  \u003cstrong\u003eSpecifications\u003c\/strong\u003e:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003e1 x stainless steel probe (150 mm in length and 2 mm in diameter)\u003c\/li\u003e\n\u003cli\u003eStainless steel Luer lock connectors for easy on and easy off\u003c\/li\u003e\n\u003cli\u003eHigh-temperature and flexible silicone alligator clip cover\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":46100581482719,"sku":"FD-PROBE-EXHAUSTPROBE","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/mainaligatorphoto.jpg?v=1720562017"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/collections\/IMG_3435x_0f70da99-c5ae-41bd-8f18-c234b29c9b37.jpg?v=1620885231","url":"https:\/\/www.forensicsdetectors.com\/en-gr\/collections\/probes.oembed","provider":"Forensics Detectors","version":"1.0","type":"link"}