{"product_id":"voc-data-logger-analyzer-usa-nist-calibration","title":"VOC Data Logger Analyzer | USA NIST Calibration","description":"\u003cp\u003e\u003cb\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/PRHwHetrT9A?si=WYeT-ioTtJyXHw89\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003eBrand:\u003c\/b\u003e FORENSICS DETECTORS\u003cbr\u003e\u003cb\u003eModel: \u003c\/b\u003eFD-600M-VOC\u003cbr\u003e\u003cb\u003e\u003cspan class=\"s1\"\u003eData Logging:\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/pages\/fd-600m\"\u003eClick Here\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan class=\"s2\"\u003e\u003cstrong\u003eUser Manual: \u003c\/strong\u003e\u003c\/span\u003e\u003c\/b\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/600M_Manual_v1.0.pdf\"\u003e\u003cspan class=\"s2\"\u003eClick Here\u003c\/span\u003e\u003c\/a\u003e\u003cb\u003e\u003cbr\u003eBlog Article: \u003c\/b\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/blogs\/articles\/voc-detector-air-quality\" target=\"_blank\"\u003eClick Here\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e📊 \u003cstrong\u003eGAS DATA\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e LOGGER:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eData logging functions with built-in TF Memory Card (512MB) able to store 1,000,000 logs, equivalent to 277 hours at 1 sample\/sec. \u003c\/span\u003e\u003cbr\u003e🎆 \u003cstrong\u003eDETECT:\u003c\/strong\u003e VOC analyzer measuring 0-100 ppm with 1 ppm resolution.\u003c\/li\u003e\n\u003cli\u003e🌈 \u003cstrong\u003eCOLOR DISPLAY:\u003c\/strong\u003e Color screen and graph functions allow for easy and intuitive operation.\u003c\/li\u003e\n\u003cli\u003e📲 \u003cstrong\u003eALARMS:\u003c\/strong\u003e Adjustable low and high alarms.\u003c\/li\u003e\n\u003cli\u003e💪 \u003cstrong\u003eSTRONG:\u003c\/strong\u003e Robust design constructed with high-strength ABS and anti-slip grip rubber. Water-resistant, dust-resistant, and explosion-proof.\u003c\/li\u003e\n\u003cli\u003e🕵️ \u003cstrong\u003eTRUSTWORTHY:\u003c\/strong\u003e 1-year limited warranty. Arrives with a signed and dated calibration certificate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDetails:\u003c\/strong\u003e Looking for a top-quality VOC data logger? This is it. It has the advanced features of a high-end VOC gas analyzer with graphing and data logging functionality. The data logging function is built in which means the unit can run by itself and the data will be captured by its internal \u003cspan\u003eMemory Card (512MB) that can store 1,000,000 logs, equivalent to 277 hours at 1 sample\/sec. The internally logged data is then retrieved by connecting a Type C USB cable to a computer and viewing the logged *.CSV files, just like you would with an external USB drive. Very easy and simple, with no extra software required. The *.CSV file can then be imported into EXCEL to graph and manipulate as required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you want it to data log continuously with a long sample rate, then no problem. Just set the sample rate to a large value and plug the unit into cable power so it is always charging ON, and you are good to go for many days of sampling. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis powerful analyzer has a built-in pump allowing for super-fast VOC detection \u0026amp; response and comes with a 4ft probe that is perfect for sampling gas in indoor or outdoor areas. Customers use it for tracking indoor VOC levels. If you require a more basic \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/volatile-organic-compounds-detector\"\u003eVOC detector,\u003c\/a\u003e we recommend our handheld VOC meter.  For those that don't require a data logger function, then a more\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/voc-analyzer-usa-nist-calibration\"\u003e affordable VOC analyzer\u003c\/a\u003e is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e VOC Data Logger Analyzer, User manual, USB charging cable, charger, analyzer case, 4ft telescopic stainless probe, tubing, and certified calibration certificate.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCalibration Options:  \u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/hydrogen-sulfide-bump-gas\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.forensicsdetectors.com\/products\/single-gas-calibration\" target=\"_blank\"\u003eCalibration Service by Forensics Detectors\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/pages\/fd-600m-1\"\u003eCalibration Tutorial (DIY)\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCalibration Kit\u003c\/strong\u003e \u003cstrong\u003e(DIY sold separately):\u003c\/strong\u003e\u003cbr\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.forensicsdetectors.com\/products\/voc-gas-50-ppm\" target=\"_blank\"\u003eCalibration Gas (VOC)\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.forensicsdetectors.com\/products\/t-piece-and-tubing\" target=\"_blank\"\u003eCalibration T-piece \u0026amp; Tubing\u003c\/a\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.forensicsdetectors.com\/products\/gas-regulator-fixed-flow-0-5lpm-c10\" target=\"_blank\"\u003eCalibration Gas Regulator (C10)\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/isobutylene-voc-bump-gas\"\u003eBump Gas (VOC)\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAccessories \u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e(sold separately):\u003c\/strong\u003e \u003c\/span\u003e\u003cbr\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.forensicsdetectors.com\/products\/detector-stand-universal\" target=\"_blank\"\u003eGas Detector Stand\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/probe-stainless-steel-telescopic\"\u003eTelescopic Probe\u003c\/a\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.forensicsdetectors.com\/products\/single-gas-calibration\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.forensicsdetectors.com\/products\/silicone-tubing-3ft\"\u003eTubing (3ft)\u003c\/a\u003e\u003ca rel=\"noopener\" href=\"https:\/\/www.forensicsdetectors.com\/products\/single-gas-calibration\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003cspan\u003eGas Sensor Replacement (VOC) (email us)\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eVolatile Organic Compounds (VOC) Range:\u003c\/strong\u003e 0 - 100 ppm with 1 ppm resolution\u003cbr\u003e\u003cstrong\u003eGas Sensor Type:\u003c\/strong\u003e Electrochemical Gas Sensor\u003cbr\u003e\u003cspan\u003e\u003cstrong\u003eGas Sensor Life:\u003c\/strong\u003e 2 to 3 years\u003cbr\u003e\u003cstrong\u003eError:\u003c\/strong\u003e \u0026lt;±5% F.S.\u003cbr\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 30 seconds\u003cbr\u003e\u003cstrong\u003eStore \/ Operating Temp:\u003c\/strong\u003e\u003cspan\u003e 0°F - 122°F\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eStore \/ Operating Humidity:\u003c\/strong\u003e\u003cspan\u003e \u0026lt;95%RH\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003eBattery:\u003c\/strong\u003e DC3.7V Li-Ion battery 4000mAh\u003cbr\u003e\u003cstrong\u003eCharging Time:\u003c\/strong\u003e 4 hours\u003cbr\u003e\u003cstrong\u003eOperation Time:\u003c\/strong\u003e \u0026gt; 5 hours\u003cbr\u003e\u003cstrong\u003eDimension\/Weight:\u003c\/strong\u003e 9.09 x 3.43 x 2.36 inches, 800grams\u003cbr\u003e\u003cstrong\u003eRating:\u003c\/strong\u003e ATEX certified Ex ib IIC T4 Gb. IP65.\u003cbr\u003e\u003cstrong\u003ePump Noise:\u003c\/strong\u003e \u0026lt;60dB\u003cbr\u003e\u003cstrong\u003ePump Flow Rate:\u003c\/strong\u003e 0.3 to 0.7 LPM\u003cbr\u003e\u003cstrong\u003eInlet Air Barb:\u003c\/strong\u003e 3mm (1\/8 inch) outer diameter barb\u003cbr\u003e\u003cstrong\u003eCharger Port:\u003c\/strong\u003e USB Type C (use at least 1A\/5V charger)\u003cbr\u003e\u003cstrong\u003eDisplay:\u003c\/strong\u003e 3.5-inch color HD display\u003cbr\u003e\u003cstrong\u003eProbe Length:\u003c\/strong\u003e 4ft Telescopic Probe\u003cbr\u003e\u003cstrong\u003eRecommended Calibration Period: \u003c\/strong\u003e12 months\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003cstrong\u003eCarry Case Weight:\u003c\/strong\u003e 3.1 lb with analyzer \u0026amp; accessories\u003cbr\u003e\u003cstrong\u003eCarry Case Dimensions:\u003c\/strong\u003e 9 x 7 x 5 inches\u003cbr\u003e\u003cstrong\u003eAlarm:\u003c\/strong\u003e LED, Buzzer, and Vibration\u003cbr\u003e\u003cstrong\u003eCalibration Location (USA):\u003c\/strong\u003e Los Angeles, California, USA\u003cbr\u003e\u003cstrong\u003eCalibration Standard (USA):\u003c\/strong\u003e USA NIST Traceable Gas Source\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003cstrong\u003eCalibration Location (Europe):\u003c\/strong\u003e Athens, Greece\u003cbr\u003e\u003cstrong\u003eCalibration Standard (Europe):\u003c\/strong\u003e European NPL Traceable Gas Source\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"FORENSICS DETECTORS","offers":[{"title":"Default Title","offer_id":44979987742943,"sku":"FD-600M-VOC","price":995.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/3012\/7408\/files\/Image1-FD-600M-VOC-Shopify.jpg?v=1770213667","url":"https:\/\/www.forensicsdetectors.com\/en-gr\/products\/voc-data-logger-analyzer-usa-nist-calibration","provider":"Forensics Detectors","version":"1.0","type":"link"}