Oxygen Analyzer | Leak Purge & Weld Monitor (100 ppm)


Price:
Sale price€595,00
Stock:
In stock (942 units), ready to be shipped

Brand: FORENSICS DETECTORS
Model: 
FD-600-O2-LEAK
Data Logging: Click Here
User Manual (PDF):
EN | DE | FR | ES | IT |
Application Guide:
Blog explanation

Features:

  • 🎆 USES: Used for precise oxygen depletion analysis, welding purge analysis, and argon or nitrogen leak detection: High-quality electrochemical oxygen sensor. Comes FACTORY-CALIBRATED.
  • 🌈 COLOR DISPLAY: Color screen and graph functions allow for easy and intuitive operation.
  • 📲 DATA LOGGING: USB recharging and real-time data acquisition. Arrives with silicone tubing, a stainless probe, and a filter.
  • 💪 STRONG: Shockproof, water-resistant, dustproof, and explosion-proof.
  • 🕵️ TRUSTWORTHY: 1-year limited warranty. Arrives with a signed and dated calibration certificate. 

Details: You don't need to break the bank for a quality 0.01% (100 ppm) resolution oxygen detector for O2 depletion analysis for TIG or MIG welding. The FORENSICS oxygen analyzer is an excellent option for those who would like to confirm low oxygen content in inert environments. The device accurately monitors oxygen levels while using inert gas to purge stainless steel, titanium, and other reactive metals.

  • When welding, the objective is to remove as much oxygen as possible.
  • The best welding results occur when there is no oxidation, hence the need for minimal oxygen levels.
  • Weld oxidation degrades the mechanical properties of a pipe and reduces its resistance to corrosion.
  • To reduce this oxidation, the oxygen content must be dramatically lowered.

The oxygen gas analyzer measures the oxygen content in the weld chamber down to 0.01% (100 ppm). Based on our industrial analyzer platform, the built-in pump is easy to use, light, and very portable. Simply insert the probe into the tubing with the filter and onto the analyzer barb. The user has full pump control, withdrawing small or large quantities of air with the built-in pump. The analyzer has a color screen, large digits, and on-screen real-time graphing. The detector is built using an advanced electrochemical oxygen sensor. The internal 32-bit microprocessor allows for user calibration, ON/OFF flow, and test control.

Included: O2 analyzer and magnet back, user manual, certified calibration certificate, USB charging cable, charger, 1 x 3inch stainless needle probe, particle filter, and 3 ft silicone tubing.

Calibration Options:  
1. Professional Calibration: Serviced by Forensics
2. Calibration Guide: Calibrate It Yourself

Calibration Kit Items (needed to calibrate yourself - sold separately):
Calibration T-piece & Tubing
Calibration Gas (N2)
Calibration Gas Regulator (C10)
Bump Gas (N2)

Accessories (sold separately):  
Gas Sensor Replacement (O2)
Gas Detector Waterproof Case
Gas Detector Stand
Air Gas Sample Probe
Tubing

Specifications

Oxygen (O2) Detection: 0 - 30% with 0.01% resolution
Gas Sensor Type: Electrochemical Gas Sensor
Gas Sensor Life: 2 - 3 years
Sampling Type: Pumped (built-in sampling pump)
Recommended Calibration Period:
12 months
Datalogging: Yes (instructions included)
Error: ≤ ± 3% F.S.
Response Time: < 30 seconds
Store / Operating Temp: 0 to 122°F (−18 to 50°C)
Store / Operating Humidity: 
<95%RH
Battery: DC 3.7V Li-ion battery, 3200 mAh
Explosion Rating: ATEX certified Ex ib IIC T4 Gb (PDF)
Weight: 14 oz (400 g)
Dimensions: 5.1 × 2.6 × 1.2 inches (13.0 × 6.6 × 3.0 cm)
Charge Time: 4 hours
Operating Time: > 10 hours
Minimum Required Headspace Volume: 200ml
Pump Rate: 0.1 LPM - 0.3 LPM (100 - 300 cc/min)
Alarm: LED Alarm
Calibration Location (USA): Los Angeles, California, USA
Calibration Standard (USA): USA NIST Traceable Gas Source
Calibration Location (Europe): Athens, Greece
Calibration Standard (Europe): European NPL Traceable Gas Source