Acid Gas Vapor Detector | USA NIST Calibration

  • Sale
  • $499.00
  • Regular price $899.00



Brand: FORENSICS DETECTORS
Model: FD-90A-ACID
User Manual: Click Here 
Blog Article: Click Here

Features:

  • ⚛️ DETECT: This gas detector is sensitive to acidic gases and vapors such as acetic acid (C2H4O2), hydrochloric acid (HCl), sulfuric acid (H2SO4), hydrofluoric acid (HF), nitric acid (HNO3), peracetic acid (C₂H₄O₃) and formic acid (CH2O2).
  • 🎆 ALARMS: Adjustable audio, visual, and vibration alarms alert when preset levels are reached. Alarms come with digital time stamping and logging.
  • 💪 STRONG: Shockproof, water-resistant, dustproof, and explosion-proof with belt clip.
  • 🕵️ TRUSTWORTHY: ** 1-year limited warranty ** Arrives with calibration and QA certificates ** Product tested and verified in the USA ** 

Details: The professional acidic gas and vapor detector.  This gas detector is sensitive to acidic gases and vapors such as acetic acid (C2H4O2), hydrochloric acid (HCl), sulfuric acid (H2SO4), hydrofluoric acid (HF), nitric acid (HNO3), peracetic acid (C₂H₄O₃) and formic acid (CH2O2). Tracking and monitoring acidic gases is important in processing, spot checking, indoor vapor cloud checking, laboratory, and personal safety. The unit comes factory-calibrated to HCl acidic gas. Advanced features such as temperature detection, alarm recording, alarm setting, backlight high-resolution LCD, calibration features, and others are included.

Included: Gas detector, belt clip, sling, English manual, USB charging cable, calibration cover, and USA NIST calibration certificate.

Calibration Kit
Calibration Gas (SO2) (Surrogate Gas 10ppm SO2 : 20ppm ACID is used for calibration. A SO2 NIST gas standard is employed since none exists for generic ACID vapor)
Calibration Gas Regulator (C10)
Bump Gas (SO2)
Tubing

Calibration Service: 
Gas Detector Calibration Service (single gas)

Accessories (sold separately): 
Pump and Probe
Gas Detector Hard Case
Gas Detector Pouch
Gas Detector Stand
Gas Sensor Replacement (email us)

Specifications

Acid Gas and Vapor Detection: (calibrated to USA NIST sulfur dioxide SO2 gas). Sensitive to acidic gases and vapors such as acetic acid (C2H4O2), hydrochloric acid (HCl), sulfuric acid (H2SO4), hydrofluoric acid (HF), nitric acid (HNO3), peracetic acid (C₂H₄O₃) and formic acid (CH2O2).
Detection Range: 0 - 20 ppm with 0.1 ppm resolution
Accuracy: ≤ ± 5% F.S.
Response Time: T < 30 sec
Operating Temperature: 0F - 122F
Operating Humidity: < 95% RH non-condensing
Voltage: DC 3.7V Li-battery 1500 mAh
Working Time: > 24 hours
Charging Time: 4 hours
Protection Category: IP65
Weight: about 130 g (including battery)
Calibration Standard: USA NIST Source
Recommended Calibration Period: every 6 to 12 months
Gas Sensor Type: Electrochemical
Gas sensor life: 2 - 3 years